Sick Limit Switch

Our product range includes a wide range of i110p sick limit switch, i 16 s sick limit switch, i200-m0413 sick limit switch and i 110p 1 asick limit switch.

I110P Sick Limit Switch

Request Callback

₹ 1890 / Piece Get Latest Price

Product Brochure
Sensor TypeInductive
Output TypePNP
Switching ModeNO
Usage/ApplicationVending Machine
Switch TypeRotary Limit Switch
BrandSick
Ambient Operating Temperature-25 Deg C +80 Deg C
Rated Insulation Voltage250 V
Weight0.43 kg
Housing MaterialZinc Diecast
Model Numberi110P
Mechanical Life10 x 10 6 switching cycles
Rated operating current3 A
Switching VoltageLess Than Equal 5 V DC
Specifications:
Number of positive action N/C contacts 2
Number of N/O contacts 2
Actuation force ≥ 11 N
Actuation frequency ≤ 6,000 /h
Actuation directions 4
Approach speed 0.1 m/min ... 15 m/min
Positive break travel 4 mm


Safety-related Parameters:

B10d parameter 2 x 106 switching cycles (with small load)
Type Type 1 (EN ISO 14119)
Actuator coding level Uncoded (EN ISO 14119)
Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.


Interfaces:
Connection type Cable gland, 1 x M20
Conductor cross-section ≤ 2.5 mm²

i 16 S Sick Limit Switch

Request Callback

₹ 1980 / Piece Get Latest Price

Product Brochure
BrandSick
Usage/ApplicationMachine Tools
Switch TypeRotary Limit Switch
Ambient Operating Temperature-20 Deg C +80 Deg C
Rated Insulation Voltage240 V
Weight0.14 kg
Rated Impulse Withstand Voltage2,500 V
Model Numberi 16 S
Rated Operating Current3 A
Switching VoltageLess Than Equal 5 V DC
Mechanical Life1 x 10 6 switching cycles
Storage Temperature-20 Deg C +80 Deg C
Features:
Number of positive action N/C contacts 2
Number of N/O contacts 0
Retaining force ≤ 30 N
Actuation frequency ≤ 7,200 /h
Actuation directions 3
Approach speed ≤ 10 m/min


Safety-related Parameters:
B10d parameter 2 x 106 switching cycles (with small load)
Type Type 2 (EN ISO 14119)
Actuator coding level Low coding level (EN ISO 14119)
Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.


Interfaces:
Connection type Cable gland, 3 x M20
Conductor cross-section ≤ 1.5 mm²

I200-M0413 Sick Limit Switch

Request Callback

₹ 1280 / Piece Get Latest Price

Product Brochure
Actuator TypeRoller Lever
Contact Type1 NO+1 NC
Enclosure RatingIP65
Usage/ApplicationMachine Tools
Switch TypeRotary Limit Switch
BrandSick
Model Name/Numberi200-M0413
Ambient Operating Temperature-20 Deg C +60 Deg C
Rated Insulation Voltage500 V
Weight0.55 Kg
Rated Operating Current3 A
Power ConsumptionLess Than Equal 7 W
Short-Circuit Protection3 A gG
Switching VoltageLess Than Equal 5 V DC
Switching CurrentLess Than Equal 5 mA (5 V DC)
Switch-on Time of Magnet100 %
Features:
Number of positive action N/C solenoid monitoring contacts 2
Number of N/O solenoid monitoring contacts 0
Number of positive action N/C door monitoring contacts 2
Number of N/O door monitoring contacts 1
Number of N/C door monitoring contacts 0
Locking force Fmax 2,600 N (EN ISO 14119) 1)
With straight actuator EN ISO 14119
With angled actuator EN ISO 14119
With hinged actuator EN ISO 14119
Locking force FZh 2,000 N (EN ISO 14119)
Actuation frequency ≤ 3,600 /h
Actuation directions 3
Approach speed ≤ 10 m/min
  • Only in combination with the delivered fixing screws, otherwise 1950 N.

Safety-Related Parameters:
B10d parameter 2 x 106 switching cycles (with small load)
Type Type 2 (EN ISO 14119)
Actuator coding level Low coding level (EN ISO 14119)
Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.


i 110P 1 ASick Limit Switch

Request Callback

₹ 1980 / pcs Get Latest Price

Product Brochure
BrandSick
Usage/ApplicationMachine Tools
Switch TypeRotary Limit Switch
Rated Insulation Voltage30 V
Rated Impulse Withstand Voltage1.5 kV
Short Circuit Protection Device1 A gG
Model Numberi 110P
Thermal Current1 A
Wire Cross-Section0.34 mm-21.5 mm2
Min. Switching Voltage12 V
Min Switching Current1 mA
Conditional Rated Short-Circuit Current100 A
Solenoid Supply VoltageAC/DC 24 V
Max Solenoid Power8 W
Other Details:
Model NO. i10-E0313S02

Number of positive action N/C solenoid monitoring contacts
2
Number of N/O solenoid monitoring contacts 0
Number of positive action N/C door monitoring contacts 1
Number of N/O door monitoring contacts 1
Number of N/C door monitoring contacts 0
Locking force Fmax 1,300 N (EN ISO 14119)
With straight actuator EN ISO 14119
With angled actuator EN ISO 14119
With hinged actuator EN ISO 14119
Locking force FZh 1,000 N (EN ISO 14119)
Actuation force ≥ 10 N
Actuation frequency ≤ 7,000 /h
Actuation directions 4
Approach speed ≤ 20 m/min


Safety-related Parameters:
B10d parameter 3 x 106 switching cycles (with small load)
Type Type 2 (EN ISO 14119)
Actuator coding level Low coding level (EN ISO 14119)
Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.