- +5
Get Best Quote
![]() | M/s Antech Engineers
Near Hero Honda Chowk, Gurgaon, Gurugram, Haryana GST No. 06AIZPT6243K1ZC |
Approx. 1,290 / pcs Get Latest Price
Product BrochureBrand | Sick |
Usage/Application | Machine Tools |
Switch Type | Rotary Limit Switch |
Model Name/Number | i200-M0413 |
Ambient Operating Temperature | -20 Deg C +60 Deg C |
Rated Insulation Voltage | 500 V |
Weight | 0.55 Kg |
Rated Operating Current | 3 A |
Power Consumption | Less Than Equal 7 W |
Short-Circuit Protection | 3 A gG |
Switching Voltage | Less Than Equal 5 V DC |
Switching Current | Less Than Equal 5 mA (5 V DC) |
Switch-on Time of Magnet | 100 % |
Number of positive action N/C solenoid monitoring contacts | 2 | ||||||||
Number of N/O solenoid monitoring contacts | 0 | ||||||||
Number of positive action N/C door monitoring contacts | 2 | ||||||||
Number of N/O door monitoring contacts | 1 | ||||||||
Number of N/C door monitoring contacts | 0 | ||||||||
|
|||||||||
|
|||||||||
Actuation frequency | ≤ 3,600 /h | ||||||||
Actuation directions | 3 | ||||||||
Approach speed | ≤ 10 m/min |
B10d parameter | 2 x 106 switching cycles (with small load) |
Type | Type 2 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Approx. 1,890 / pcs Get Latest Price
Product BrochureBrand | Sick |
Usage/Application | Vending Machine |
Switch Type | Rotary Limit Switch |
Ambient Operating Temperature | -25 Deg C +80 Deg C |
Rated Insulation Voltage | 250 V |
Weight | 0.43 kg |
Model Number | i110P |
Housing Material | Zinc Diecast |
Mechanical Life | 10 x 10 6 switching cycles |
Rated operating current | 3 A |
Switching Voltage | Less Than Equal 5 V DC |
Number of positive action N/C contacts | 2 |
Number of N/O contacts | 2 |
Actuation force | ≥ 11 N |
Actuation frequency | ≤ 6,000 /h |
Actuation directions | 4 |
Approach speed | 0.1 m/min ... 15 m/min |
Positive break travel | 4 mm |
B10d parameter | 2 x 106 switching cycles (with small load) |
Type | Type 1 (EN ISO 14119) |
Actuator coding level | Uncoded (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
|
Approx. 1,980 / pcs Get Latest Price
Product BrochureBrand | Sick |
Usage/Application | Machine Tools |
Switch Type | Rotary Limit Switch |
Rated Insulation Voltage | 30 V |
Rated Impulse Withstand Voltage | 1.5 kV |
Short Circuit Protection Device | 1 A gG |
Model Number | i 110P |
Thermal Current | 1 A |
Wire Cross-Section | 0.34 mm-21.5 mm2 |
Min. Switching Voltage | 12 V |
Min Switching Current | 1 mA |
Conditional Rated Short-Circuit Current | 100 A |
Solenoid Supply Voltage | AC/DC 24 V |
Max Solenoid Power | 8 W |
Model NO. i10-E0313S02 Number of positive action N/C solenoid monitoring contacts |
2 | ||||||||
Number of N/O solenoid monitoring contacts | 0 | ||||||||
Number of positive action N/C door monitoring contacts | 1 | ||||||||
Number of N/O door monitoring contacts | 1 | ||||||||
Number of N/C door monitoring contacts | 0 | ||||||||
|
|||||||||
|
|||||||||
Actuation force | ≥ 10 N | ||||||||
Actuation frequency | ≤ 7,000 /h | ||||||||
Actuation directions | 4 | ||||||||
Approach speed | ≤ 20 m/min |
B10d parameter | 3 x 106 switching cycles (with small load) |
Type | Type 2 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Approx. 1,980 / Pcs Get Latest Price
Product BrochureBrand | Sick |
Usage/Application | Machine Tools |
Switch Type | Rotary Limit Switch |
Ambient Operating Temperature | -20 Deg C +80 Deg C |
Rated Insulation Voltage | 240 V |
Weight | 0.14 kg |
Rated Impulse Withstand Voltage | 2,500 V |
Model Number | i 16 S |
Rated Operating Current | 3 A |
Switching Voltage | Less Than Equal 5 V DC |
Mechanical Life | 1 x 10 6 switching cycles |
Storage Temperature | -20 Deg C +80 Deg C |
Number of positive action N/C contacts | 2 |
Number of N/O contacts | 0 |
Retaining force | ≤ 30 N |
Actuation frequency | ≤ 7,200 /h |
Actuation directions | 3 |
Approach speed | ≤ 10 m/min |
B10d parameter | 2 x 106 switching cycles (with small load) |
Type | Type 2 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
|